香蕉国产在线-香蕉国产线观看-香蕉国产人午夜视频在线观看-香蕉国产人午夜视频在线-香蕉国产精品偷在线播放-香蕉国产精品

product details

IGF type fluorine lined pipeline pump

Product features

1. The pump is of vertical structure, with the same inlet and outlet diameters and located on the same central line. If equipped with protective cover, it can be used outdoors.

2. The impeller is directly installed in the motor bearing, which can effectively balance the radial and axial load generated by pump operation, thus ensuring the pump running balance and low vibration noise.

3. The shaft seal adopts the combination of ordinary and particle resistant mechanical seal and mechanical seal, which can effectively increase the service life of mechanical seal.

4. The pump can be operated in series or in parallel according to the requirements of flow and head.


021-62586878

Product overview

Fluoroplastics is the world's outstanding corrosion-resistant materials, I choose the material production of IGF type fluorine lining pipeline pump. Combined with the domestic better hydraulic model and the performance parameters of is centrifugal pump, it is designed by ingenious combination on the basis of general vertical pump. The product has strong corrosion resistance, can replace 316L stainless steel, titanium alloy and other precious metals, and has the advantages of high efficiency, energy saving, low noise and reliable performance.

Product features

1. The pump is of vertical structure, with the same inlet and outlet diameters and located on the same central line. If equipped with protective cover, it can be used outdoors.

2. The impeller is directly installed in the motor bearing, which can effectively balance the radial and axial load generated by pump operation, thus ensuring the pump running balance and low vibration noise.

3. The shaft seal adopts the combination of ordinary and particle resistant mechanical seal and mechanical seal, which can effectively increase the service life of mechanical seal.

4. The pump can be operated in series or in parallel according to the requirements of flow and head.

Design features

(1) The pump is a vertical structure, with the same inlet and outlet diameters, and located on the same central line. It can be installed in the pipeline like a valve. It has compact and beautiful appearance, small floor area and low construction investment. If the protective cover is added, it can be used outdoors.

(2) The impeller is directly installed on the lengthened shaft of the motor, with short axial size and compact structure. The reasonable allocation of pump and motor bearing can effectively balance the radial and axial load generated by pump operation, thus ensuring the stable operation of the pump and low vibration noise.

(3) The shaft seal adopts mechanical seal or mechanical seal combination, adopts imported titanium alloy seal ring, medium high temperature mechanical seal and hard alloy material, wear-resistant seal, which can effectively increase the service life of mechanical seal.

(4) It is convenient to install and maintain, without removing the pipeline system. All rotor components can be extracted by removing the nut of pump coupling seat.

(5) The pump can be operated in series or in parallel according to the requirements of flow and head.

(6) According to the requirements of pipeline layout, vertical and horizontal installation of pump can be adopted.


model

Flow m3/h

Lift m

Matching power kw

In and out diameter

Rotational speed r/min

IGF40-125

6.3

20

1.5

40

2900

IGF40-125A

5.6

16

1.5

40

2900

IGF40-160

6.3

32

2.2/3

40

2900

IGF40-160A

5.9

28

1.5/2.2

40

2900

IGF50-125

12.5

20

2.2

50

2900

IGF50-125A

11

16

2.2

50

2900

IGF50-160

12.5

32

2.2/3

50

2900

IGF50-160A

11.7

28

2.2/3

50

2900

IGF65-125

25

20

3/4

65

2900

IGF65-125A

22.3

16

3

65

2900

IGF65-160

25

32

4/5.5

65

2900

IGF65-160A

23.4

28

4/5.5

65

2900

IGF80-125

50

20

5.5/7.5

80

2900

IGF80-125A

45

16

5.5

80

2900

IGF80-160

50

32

7.5/11

80

2900

IGF80-160A

46.7

28

7.5/11

80

2900


IGF type fluorine lined pipeline pump is suitable for long-term transportation of acid, alkali, oxidant and other corrosive liquids of any concentration under the temperature of - 85 ℃ ~ + 200 ℃. GF is used in petroleum, chemical, metallurgy, electric power, papermaking, flue gas desulfurization, dust removal, food, pharmaceutical and synthetic fiber sectors

Related information

Address:576 Wuding Road, Jing'an District, Shanghai

E-mail:info@xinguangminggroup.com

主站蜘蛛池模板: 果冻传媒在线播放观看228集 | 丰腴尤物贵妇浪荡小说 | 99 久久99久久精品免观看 | 久草色视频| 奇米影视999| 99热这里只有精品国产在热久久 | 2020韩国三级理论在线观看 | 美女脱了内裤打开腿让你桶爽 | 精品久久一区 | 成人私人影院在线观看网址 | 午夜毛片在线观看 | 日本无遮挡拍拍拍凤凰 | 国内久久婷婷综合欲色啪 | 欧美精品v日韩精品v国产精品 | 免费国产好深啊好涨好硬视频 | 免费高清视频免费观看 | 香蕉成人999视频 | gangbang日本| 99国产小视频 | 禁忌第一季第3季 | 好大好爽好舒服视频 | 五月一区二区久久综合天堂 | 天天干夜夜添 | 国产激情久久久久影院小草 | aⅴ导航站 | 亚洲国产精品嫩草影院永久 | 免费视频左左视频 | 精品视频在线免费播放 | 青草国产在线观看 | 成人伊人青草久久综合网破解版 | 欧美5g影院| 91影视永久福利免费观看 | www久久com | 日韩精品一区二区三区视频 | 国产精品一区二区久久 | 92国产福利视频一区二区 | 男女视频在线观看 | 日韩国产欧美一区二区三区 | 亚洲国产99在线精品一区二区 | 成人二区| 九九热在线视频观看这里只有精品 |